Control and monitoring systems for temperature, humidity and environmental factors Server rooms are generally not deterrent systems, although Pishran Sanat Vira has control and deterrent technology in this regard. The use of these systems is necessarily due to the fact that the manager or server room keeper is able to know the nature and extent of the incident in different ways at the moment of the incident so that he can react appropriately to that incident.
Server room alarm systems because they are able to detect factors such as temperature increase, humidity increase, presence of water, smoke and fire, cooling system fuse cutting, split system compressor burning, unauthorized access control, etc. warn in different ways, so the server room manager and maintainer will not have to worry about the condition and stability of the server room when they are not present at their organizational location.
Also, in some systems for controlling and monitoring the environmental conditions of the server room, highly advanced technologies are used to control the system automatically and make decisions in critical situations, such as the one implemented in Pishran Sanat Vira Company [automatic control system for coolers]https://pishrans.com/مقالات/172-smart-cooling-for-server-room)) that can manage the operation takes charge of the coolers and at specific times for periodic operation in order to reduce the depreciation of refrigeration devices, move them with reserve systems. Also, this mechanism is able to intelligently replace the cooler in case of a problem for a cooler until the problem is solved. Activate in the circuit
Also, this system is able to create the minimum electricity consumption and depreciation with the minimum cooling load that it puts on the coolers. Also, if the temperature increases in the hot seasons of the year, the system is able to automatically increase the amount of condensers or sprinklers in the network and achieve high efficiency. creates
In another part, the control and automation systems of the server room, which are designed with modern knowledge, are able to use an inhibitory mechanism in the event of a fire, in addition to creating an alarm, which is to cut off the electricity from the entrance to the server room. The source of the fire, which is electricity, should be cut off upon arrival and the acceleration of the fire should be prevented along with the fire extinguishing system, and it should be considered as an aid to the fire extinguishing system.
In examples, you can use advanced touchscreen displays in server room monitoring systems. %D9%84%D8%A7%D8%AA/540-src-color-hmi) used for guard rooms or night guards so that all alarms can be heard and commented on and they have a special control in these matters.
Supported sensors
1) Temperature
2) Humidity
3) Grid electricity
4) UPS power
5) Smoke
6) Fire
7) Water leakage
8) The door of the server room remains open
9) Unauthorized entry to the server room
10) hitting the rack or opening the rack door
11) Fire inside the rack or electrical panels
12) Three-phase electricity
13) Refrigeration system electricity
Company | پیشران صنعت ویرا |
---|---|
Tel | +98 21-4×××3681, +98 21-4×××5128, +98 21-4×××5809, +98 21-4×××583 |
Whatsapp link | |
Instagram page | |
Telegram | Telegram link |
Website | http://www.pishrans.com |
Country | Iran |
Province | Tehran |
Address | تهران –بزرگراه ستاری جنوب به شمال-بعد از حکیم –نبش کوچه اسدی –پلاک41 –واحد 10 |