Server room control system or bms server room intelligence
In the design of src control systems, in addition to sending warnings in case of errors and displaying information online and offline and recording information, another function is added to the system so that when needed, along with monitoring various errors, there is the ability to define hardware reactions.
Server room environment condition monitoring system or server room monitoring mechanism bms
In this system, there will be a logical definition in the output according to practically every error so that the problems can be solved as much as possible without the presence of human resources. These errors can be things like the following.
1) The temperature increases
After turning on the siren and sending an SMS, the reserve cooler will be turned on in the network and if the temperature does not decrease with the reserve cooler, it will send an alarm to the manager of critical conditions.
2) humidity increases
This happens very rarely, because the increase in humidity is generally done by cutting off the cooling system, and according to calculations, the trend of humidity changes in a system will be a downward trend with increasing temperature, so this case is practically ruled out, but the presence of a humidity sensor is a security factor for the degree of protection. higher in the system
3) The network power is cut off
In this case, after sending the warning, if there is a generator or UPS system for cooling, it will start cooling.
4) Water leaks
In very large systems, where the cooling function is a water circulation process, water leakage can cause the destruction of the entire system, and if there is a water leak, it can close the inlets and outlets of the water from the desired location so that the leakage does not cause damage, and in the end, electricity Automatically disconnect the entire server room from the source (main fuse) so as not to cause a connection
5) System electricity is 2 phase
In 3-phase industrial equipment such as UPS and similar, 2-phase network can lead to UPS burning, which can be neutralized and ineffective by cutting off the entire network power.
6) The single-phase network becomes 2-phase
Smartening with BMS by creating an alarm due to a connection in the high voltage power lines, the neutral wire is also energized and 380 V electricity enters the network. cause severe damage to the main network that is connected to it. If this happens, the power supply to the system must be cut off without delay, which can be done by control systems.
7) Unauthorized access to the network is done
In this case, after activating the alarm and sending the SMS, the system should practically stop the unknown person who can close the electrical outlet or entrance.
8) Sudden increase in temperature in the place
Controlling the temperature of the server room in the event of this happening, which has irreparable consequences and indicates the occurrence of fire in one or more places, and the electrical systems of the server room must be immediately disconnected from the electrical network and the air production parts must be turned off, so that the lack of oxygen Help reduce fires
9) Sudden increase in humidity in the place without lowering the temperature
This is your time factor
Company | پیشران صنعت ویرا |
---|---|
Tel | +98 21-4×××3681, +98 21-4×××5128, +98 21-4×××5809, +98 21-4×××583 |
Whatsapp link | |
Instagram page | |
Telegram | Telegram link |
Website | http://www.pishrans.com |
Country | Iran |
Province | Tehran |
Address | تهران –بزرگراه ستاری جنوب به شمال-بعد از حکیم –نبش کوچه اسدی –پلاک41 –واحد 10 |