Web-based server room temperature control is a system that can display the environmental factors of the server room that cause damage to the room online anywhere on mobile and desktop and inform the manager of its events.
But what kind of temperature monitoring is suitable for the server room?
Companies and organizations that use server equipment inside the organizational premises always have a concern about which system is suitable for protecting the server room and equipment in the event of an error.
The answer to this question was written by the Association of Electrical and Electronics Engineers (IEEE), which is a group of researchers and experts in the above field, who have experience and knowledge in all electrical matters. The Association of Electrical and Electronics Engineers publishes information in various journals. The most famous of which is tia942 in the field of server rooms. The summary of the contents that are correctly stated and translated by this forum regarding the safety and security standards of the server room will pass your attention.
1) In order for the temperature monitoring and warning system to be a stable system, it must use the most reliable hardware for this issue, this is PLC hardware.
2) The sensors used to measure the analog parameters of temperature and humidity must send the information with Modbus protocol.
3) The digital sensors used to measure the presence or absence of a dangerous physical quantity such as water leakage or smoke should not depend on the length of the wire.
4) The used digital sensors must have the ability to expand and increase in number in the form of a star topology.
5) The warning system does not have any dependence on servers, even internal servers and its own computer to send warnings or error notifications. can be
6) The monitoring system of the modem server room should have a hardware connection with the alarm mechanism and continue to work independently of the server department, which can send an alarm without interruption even when the servers are not working properly.
7) The temperature control system of the server room regularly checks its internal mechanisms, including the display, sensors, and GSM modem, so that in case of a problem, they can diagnose and repair it before the above defect causes a critical occurrence.
These are seven features that cannot be achieved in any server room temperature and humidity monitoring and control system, but you can find all of the above in the SRC2.2 system.
\r[http://nhttp://pishrans.com/src2-2
resume](http://nhttp://pishrans.com/src2-2
resume) \r[http://nhttps://pishrans.com/projects1
Photos](http://nhttps://pishrans.com/projects1
Photos) of projects\r[http://nhttps://pishrans.com/photo-project](http://nhttps://pishrans.com/photo-project)
Company | پیشران صنعت ویرا |
---|---|
Tel | +98 21-4×××5128 |
Mobile | +98 902×××2397 |
Whatsapp link | |
Instagram page | |
Telegram | Telegram link |
Website | http://www.pishrans.com |
Country | Iran |
Province | Tehran |
Address | تهران –بزرگراه ستاری جنوب به شمال-بعد از حکیم –نبش کوچه اسدی –پلاک 41 –واحد 10 |