Server room monitoring software
The main factor in controlling the temperature of the server room or controlling the environmental conditions of the server room is the stability of the monitoring system, which the system itself, according to factors such as electrical and electromagnetic noises, temperature increase, humidity increase and decrease, dust increase, smoke or material increase Among other things, they are resistant to sudden disconnection and disconnection and do not suffer from problems and do not fail.
Unfortunately, it is not easy to distinguish a stable system from an unstable system, and any technical group can build a server room temperature monitoring and control system with little knowledge.
A) Environmental factors can cause an error notification without the existence of an error, in other words, the user receives the temperature from the fault device, and at the time of occurrence, which can be at night or midnight or even on holidays, the server room keeper is forced to visit the place. The server room works in any situation, but the physical presence of the manager or server room keeper at the site and observing the absence of problems causes the user of the server room control system to be unsure, and considering that this error happens again by chance, the user is concerned about the operation of the monitoring system. The temperature and humidity have become suspicious, and even once the alarm was sent correctly to the audience, the audience did not pay attention to it and it caused a crisis.
b) Environmental factors and noise can even disrupt the operation of a system with a low-level design and hardware and disable the server room's environmental condition control system. because the hardware of the server room monitoring system is not highly stable, it may not be operational at the time of the error and may not inform the relevant manager of the error that occurred inside the server room, moreover, this error and its occurrence can cause risks such as storage burning or loss of information, therefore, choosing a server room monitoring system with a high degree of reliability and stability is the first and most important step in choosing a server room monitoring system.
It is interesting to know that the features announced by the TIA942 protocol for server room monitoring have nothing to do with
A) The number of sensors placed in the server room
b) The accuracy of the sensors used
C. The sensitivity of the used sensors
d) Variety of used sensors including (temperature - humidity - smoke - fire - water leakage)
It does not exist and the features are specific to the basic hardware or so called system motherboard. Even in the software part, the user is free to choose the type and method of communication with the device, but what is emphasized in this protocol is necessary for security as much as possible. The basic software should use PLC (programmable logic controller). This hardware is the only hardware approved by IEEE, and the next features are considered after confirming the existence of the first feature, which is the type of hardware. Moreover, the next features implicitly confirm the use of PLC hardware and without having a PLC.