## SONEL MIC Series Insulation Testing Devices: Reference for Electrical Insulation Health Monitoring - with Retonak Shaya Support\r\n\r\n\r\nAt the heart of any safe and efficient electrical system, there is a perfect insulation. Sonel Poland, as a European pioneer in the production of advanced measurement equipment, and Rartonak Shaya, its exclusive and reputable representative in Iran, is proud to introduce the complete series of MIC insulation resistance testing devices. This collection, from compact and functional models such as MIC-2 and MIC-10 (observed on pages 6 and 7 catalogs with high IP67 high protection) to advanced devices with extensive diagnostic capabilities such as MIC-10K1 and MIC-5010 (with large displays and Bluetooth connectivity), are a comprehensive solution for all electrical industry experts.\r\n\r\n### Comprehensive Technical Description: Why is insulation test vital?\r\nInsulation resistance is a fundamental criterion for measuring the ability of a substance or system to prevent the passage of unwanted electric current. Burnout, humidity, contamination, mechanical and thermal stresses can gradually reduce the quality of insulation and lead to current leakage, energy loss, overheating, expensive equipment failure, and at worst, risks of life and fire. SONEL MIC SONEL (Mic) Sonel Series calculates high accuracy of insulation resistance by applying controlled DC voltage (from 50V in base models to 10kV and higher in advanced models) and accurate leakage measuring. This information allows engineers and technicians to monitor the insulation status in cables, motors, generators, transformers, electrical panels and other electrical equipment and take the necessary preventive measures in time.\r\n\r\n### Overall Comparative Table of the capabilities of some key models of MIC series:\r\n\r\n\r\n| Feature/Model | MIC-10k1 / Mic-5050 | MIC-5010 / MIC-5005 | MIC-5001 | MIC-2510 / MIC-25505 | MIC-30 | MIC-10 / Mic-2 |\r\n| : -------------------- | : ---------------- | : ---------------- | : -------------- : ---------------- | : -------------- : --------------\r\n| ** Maximum test voltage ** | 10kv / 5kv | 5kv | 5kv | 2.5kV | 1kv | 1kv / 500V |\r\n| ** Maximum measureable resistance ** | 40tω / 20tω | 15tω | 5tω | 2tω | 100gω | 10gω / 1999mω |\r\n| ** Diagnostic PI, DAR ** | Yes | Yes | Yes | Yes (Model 2510) Yes | Yes (only MIC-10)\r\n| ** SV, DD, Ramp ** | Yes (Model 10K1) Yes (Model 5010) Yes (ramp) | No | No | No |\r\n| ** internal memory ** | 10,000 records | 10,000 records | 990 records | 990 record (2510) | 990 records | No\r\n| ** Connect to PC ** | USB, Bluetooth® | USB, Bluetooth® | USB | USB (2510) | Radio (OR-1) No\r\n| ** Safety (CAT) ** | CAT IV 600V | CAT IV 600V | CAT IV 600V | CAT IV 600V | CAT IV 600V | CAT IV 600V |\r\n| ** Protection Degree (IP) ** | Ip67 (closed door) Ip67 (closed door) Ip65 (closed door) IP54 | IP67 | IP67 |\r\n\r\n*Note: This table of getting rid of
Tehran